Problem Statement
The customer reported repeated turbine trips during startup around 2,000–3,000 rpm. Each attempt required multiple restarts before the turbine could be synchronised and taken on load.
Key points:
This recurring issue caused operational delays, uncertainty during startup, and risks to critical rotating components.
POC Objective
Since VIB360 had been installed 24 months earlier for continuous monitoring, the objective of this focused diagnostic was to:
Measurement Setup
Key Findings
The torsional vibration analysis identified:
This matched the repeated trip events at 2,000–3,000 rpm.
Recommended Actions
Action Taken by Customer
Benefits & Outcome
Potential Financial Impact
Estimated financial benefits include:
Avoided Direct Costs
Reduced Downtime
Total Potential Savings
A realistic aggregate range:
€200,000 – €500,000
saved through: